# Healthcare Mirror Technical Submittal Checklist

Planning worksheet — not an approved specification or a statement of available certifications.

## 1. Project and model identification

- Project, destination, room reference, quantity and delivery phase.
- Proposed manufacturer model / custom configuration reference.
- Drawing number, revision, date and approval owner.
- General healthcare or separately assessed special-risk environment.

## 2. Dimensions and installed interfaces

- Overall width, height, depth and weight.
- Reflecting-surface boundaries versus outer frame dimensions.
- Glass/substrate, thickness, edge and backing specification.
- Frame material, finish sample reference and corner detail.
- Wall construction, fixing design, rear space and removal path.
- Cabinets: front, body, recess, projection and door swing separately dimensioned.
- Finished-floor reference, surrounding fixtures and accessible layout review.

## 3. Electrical and lighting, where applicable

- Voltage, frequency, input power, driver and connection location.
- CCT, CRI, stated lighting output and measurement basis.
- Switching, dimming, control compatibility and restart behavior.
- Demister or additional functions only if specifically ordered.
- Required environmental rating and certification: actual report/reference, model coverage and configuration.

## 4. Documents to request and confirm

| Record | Required? | Available? | Reference / revision | Reviewer |
| --- | --- | --- | --- | --- |
| Model specification sheet | TBC | TBC | TBC | TBC |
| Elevation, plan and section | TBC | TBC | TBC | TBC |
| Installation and service instructions | TBC | TBC | TBC | TBC |
| Electrical/lighting information | TBC | TBC | TBC | TBC |
| Relevant test or certification record | TBC | TBC | TBC | TBC |
| Finish sample / approved sample record | TBC | TBC | TBC | TBC |
| Cleaning compatibility and care guidance | TBC | TBC | TBC | TBC |
| Inspection / packing requirements | TBC | TBC | TBC | TBC |
| Warranty terms and spare-part scope | TBC | TBC | TBC | TBC |

CAD, BIM, IES and reports must be confirmed individually; this checklist does not promise their availability.

## 5. Accessibility reference

U.S. ADA §603.3: bottom of reflecting surface 40 in (1015 mm) maximum above lavatories/counters; 35 in (890 mm) maximum elsewhere. Advisory 603.3 recommends a top edge at least 74 in (1880 mm); distinguish advice from mandatory provisions. Project scope and other applicable requirements require independent design-team review.

Source: https://www.access-board.gov/ada/

## 6. Approval and release

- Record unresolved items as TBC, with owner and due date.
- Do not release a purchase order based only on concept images.
- Confirm sample approval, final model/configuration, documents and quantity schedule together.